Hybrid solar inverters with built-in MPPT

Each unit combines a pure sine wave inverter, an MPPT solar charge controller and an AC battery charger. It runs loads from solar, battery and grid or generator power, and you set charger priority, charging current and input voltage range from the LCD.

Four series cover 1.8kW to 6.2kW: SRG for 12V and 24V systems, EFP with 4kW on 24V and 120V output, SRC for 230V markets on 24V or 48V batteries, and the SRC-4000VA-US with 100–120V output and grid feed-in for North America.

Hybrid solar inverters by CNSWIPOWER

Key features

Built-in MPPT

PV open-circuit voltage up to 350V on EFP, 450V on SRG and 500V on SRC models.

Solar, battery, grid, generator

Accepts utility or generator AC; solar and grid can supply loads at the same time.

Pure sine wave output

Surge capacity of twice the rated power for motor starts; peak efficiency 93–94%.

Lithium BMS communication

RS485 port talks to the battery BMS so charging follows what the battery asks for.

Configurable from the LCD

Input voltage range, charging current, and AC or solar charger priority.

Optional WiFi monitoring

Check system status from a phone or web browser.

Models and specifications

ModelRated outputBatteryAC outputMax PV powerMPPT rangeMax PV VocMax charging current
SRG-2200VA-12V1,800W12V230V, 50/60Hz2,000W55–430V450V60A AC, 80A solar
SRG-3200VA-24V3,000W24V230V, 50/60Hz3,000W55–430V450V60A AC, 80A solar
EFP 4.0kW4,000W24V120V, 60/50Hz5,600W55–350V350V110A AC, 140A solar
SRC-5000VA4,200W24V230V, 50Hz6,200W60–450V500V120A AC + solar
SRC-7000VA6,200W48V230V, 50Hz8,000W60–450V500V120A AC + solar
SRC-4000VA-US3,600W24V100–120V, 50/60Hz4,200W60–500V500V120A AC + solar

Figures from the SRG, EFP, SRC and SRC-4000VA-US user manuals. The MPS-VX series datasheet is available on request.

General specifications

SRG seriesEFP seriesSRC-5000VA / 7000VASRC-4000VA-US
Peak efficiency94%94%93%93%
Line-mode efficiencyOver 95%Over 95%Over 95%Over 95%
Surge capacity2× rated, 5 s2× rated, 5 s2× rated, 3 s2× rated, 5 s
Transfer time10 ms UPS, 20 ms appliance mode10 ms UPS, 20 ms appliance mode10 ms UPS, 20 ms appliance mode10 ms UPS, 20 ms appliance mode
Battery charging3-stage; flooded, AGM/gel, lithium3-stage; flooded, AGM/gel, lithium3-stage; flooded, AGM/gel, lithium3-stage; flooded, AGM/gel, lithium
Grid feed-in——SupportedSupported: 90–150V, PF over 0.99, up to 97%
Operating temperature0 to 55°C0 to 55°C−10 to 50°C−10 to 50°C
Dimensions (D×W×H)405 × 286 × 96.2 mm400 × 250 × 89 mm423 × 344 × 112 mm110 × 334 × 423 mm
Net weight5 kg / 5.5 kg8.5 kg7.2 kg / 8.2 kg9 kg
CertificationOn requestCECECE

Manuals and downloads

SRG-2200VA / SRG-3200VA hybrid inverter user manualSRG-2200VA-12V, SRG-3200VA-24V
PDF, 33 pages, 4.3 MB Download
EFP hybrid inverter user manual4.0kW, 24V battery, 120V output
PDF, 39 pages, 4.5 MB Download
SRC-5000VA / SRC-7000VA hybrid inverter user manualSRC-5000VA (24V), SRC-7000VA (48V)
PDF, 40 pages, 8.0 MB Download
SRC-4000VA-US hybrid inverter user manual3.6kW, 24V battery, 100–120V output
PDF, 35 pages, 7.2 MB Download

Hybrid solar inverters we make

How a hybrid solar inverter works

During the day the MPPT controller turns PV power into battery charge and supplies loads at the same time. At night the inverter runs from the battery; when the battery reaches its low-voltage limit, the unit switches to grid or generator power and recharges from it. With everything in one housing, installation needs less wiring and wall space than separate components.

What to check before you order

PV string voltage. The open-circuit voltage of each string, at the coldest expected temperature, must stay below 350V on EFP, 450V on SRG and 500V on SRC models. For best harvest keep the operating voltage inside the MPPT range in the table above.

Battery voltage. SRG runs on 12V or 24V; EFP, SRC-5000VA and SRC-4000VA-US on 24V; and SRC-7000VA on 48V. Pair a 48V model with our 48V 100Ah LiFePO4 battery or a lead-acid bank of matching voltage.

Output voltage. SRG and SRC-5000/7000VA supply 230V. EFP supplies 120V, and the SRC-4000VA-US 100, 105, 110, 115 or 120V; both are single-phase, not 120/240V split-phase units.

Need help sizing a whole system? See our off-grid solar page or send us your load list.

Frequently asked questions

What is the difference between a hybrid inverter and an off-grid inverter?

An off-grid inverter only converts battery power to AC. A hybrid inverter adds an MPPT solar charge controller and a charger that can use grid or generator power, so one unit manages the whole system.

Can I use lithium batteries?

Yes. All three series charge flooded, AGM/gel and lithium batteries, and the RS485 port communicates with a compatible battery BMS. The SRC-4000VA-US manual lists PACE and PYLON BMS protocols.

Can the inverter run without a battery?

The EFP, SRC-5000VA and SRC-7000VA can work without batteries, powering loads directly from PV when the sun is up.

Do you have a hybrid inverter for North America?

Yes, two. The EFP gives 4kW at 120V from a 24V battery. The SRC-4000VA-US gives 3.6kW from a 24V battery, with selectable 100–120V output and grid feed-in; check your utility's interconnection rules before exporting power.

Get pricing for hybrid solar inverters

Tell us the model, input and output voltage, quantity and destination. An engineer will reply with pricing and lead time.